Continuous anomaly monitoring across every HVAC asset — from chiller trips and pump failures to filter blockages and temperature deviations. Multi-channel alerts ensure your team knows the moment something goes wrong, not hours later.
Every alert is classified by severity — ensuring critical equipment failures get immediate attention while informational alerts drive planned maintenance.
Chiller trips, pump failures, fan motor overloads, VFD faults, communication loss to controllers, and any condition that stops cooling delivery. Triggers immediate multi-channel notification.
High condenser approach, Delta-T outside design range, return air temperature deviation beyond ±2°C, CO₂ exceeding thresholds, abnormal power consumption, and efficiency degradation signals.
Dirty filter alerts, UV tube failure detection, run-hour milestones, device not reporting, scheduled maintenance reminders, and configuration changes logged for audit.
Continuous threshold monitoring and pattern analysis across the entire HVAC ecosystem.
Compressor trips, low/high pressure cutouts, oil pressure faults, refrigerant leaks, abnormal kW/Ton spikes, and approach temperature anomalies.
Fan trips, motor overload, water valve stuck, Delta-T collapse, return air deviation, filter blockage, UV tube failure, and abnormal thermal power readings.
Pump trip, VFD communication loss, dry-run protection, overload, CT fan failure, abnormal vibration patterns, and flow rate deviation from setpoint.
CO₂ exceeding ASHRAE limits, PM2.5 spikes, TVOC above safe thresholds, humidity out of range, and temperature comfort band violations per zone.
Diffuser not reporting, damper stuck open/closed, zone temperature deviation, occupancy sensor malfunction, and thermostat communication loss.
Sudden consumption spikes, off-hours energy usage exceeding baseline, meter communication failures, and billing data discrepancies.
Critical alerts push through multiple channels simultaneously to ensure no equipment failure goes unnoticed.
Instant mobile app push alerts with severity badge, asset ID, and one-tap navigation to the affected device dashboard.
Live alarm feed on the command center. Color-coded severity. Alarm history with timestamps, acknowledgments, and resolution notes.
Detailed email with alarm description, affected asset, timestamp, and recommended action. Configurable escalation for unacknowledged alarms.
SIM-based SMS for critical alarms — reaches operators even without internet connectivity. Essential for after-hours fault notification.
Continuous threshold monitoring. Pattern analysis identifies anomalies before they become failures.
Auto-categorize by severity (critical/warning/info) and asset type. Priority routing based on escalation rules.
Multi-channel alert dispatch — push, web, email, SMS. Configurable escalation if not acknowledged within set time.
Auto-failover where possible (backup pump, schedule override). Manual resolution logged with timestamp and notes.
Minutes vs. hours. Real-time detection means issues are addressed before occupants notice.
A chiller trip can overload remaining units. Early warning enables load shedding before damage.
Every hour of HVAC failure costs in occupant complaints, productivity loss, and emergency repair bills.
Pattern analysis surfaces degradation trends — schedule repairs before failures, not after.
Real-time detection. Multi-channel alerts. Auto-failover where possible.